Omron V430-F-series User Manual page 188

Auto focus multi code reader
Table of Contents

Advertisement

Output State
Definition:
Sets the active electrical state of the discrete output.
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
Normally Open
Options:
0 = Normally Open
Pulse Width
Definition:
Sets the time in 1 ms increments that the discrete output remains active.
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
500ms
Options:
0 to 65535(in 1 ms increments)
Output Mode
Definition:
Sets the condition in which the discrete output is de-activated.
Serial Cmd:
<K810,output on,output state,pulse width,output mode>
Default:
Pulse
Options:
0 = Pulse
2 = Latch Mode 2
3 = Latch Mode 3
Pulse
This is the default mode of operation in which the programmable output is activated when
the Output On condition has been met and held active for the duration of the selected
pulse width.
Latch Mode 2 (Unlatch Opposite Condition)
The programmable output is activated when the Output On condition has been met and
held active until the opposite condition selected under Output On has been met.
For example, if No-Read is enabled under Output On, the programmable output will go
active on a No-Read and remain active until the opposite condition, a good read, occurs.
Latch Mode 3 (Unlatch Re-enter Read Cycle)
The programmable output is active when the Output On condition has been met and is
held active until a new read cycle begins.
Note: All of the Output On modes are inhibited when any Output on Warning is active
for Output 1.
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
1 = Normally Closed
I/O Parameters
7-23