Omron V430-F-series User Manual page 149

Auto focus multi code reader
Table of Contents

Advertisement

UPC/EAN
Supplementals Status (UPC/EAN)
Usage:
Reads Supplementals typically used in publications and documentation.
Definition:
A supplemental is a 2 to 5 digit symbol appended to the main symbol.
When set to Enabled or Required, the reader reads supplemental code
data that has been appended to the standard UPC or EAN codes.
Serial Cmd:
<K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default:
Disabled
Options:
0 = Disabled
Disabled
UPC Supplementals will not be decoded.
Enabled
When enabled, the reader will try to decode a main and a supplemental.
Required
When set to Required, both the main and the supplemental symbols must be read.
For example, if Supplementals is set to Required, Separator is enabled, and an asterisk
is defined as the UPC separator character. Then the data is displayed as:
MAIN * SUPPLEMENTAL.
Note: Under no circumstances will the supplemental symbol data be sent without a main
symbol.
Note: If additional symbols—other than the main or supplemental—will be read in the
same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC/EAN)
Usage:
Allows users to distinguish between the main and Supplemental symbols.
Definition:
A character can be inserted between the standard UPC or EAN symbology
and the supplemental symbology when Supplementals is set to Enabled
or Required.
Serial Cmd:
<K473,UPC status,EAN status,supplementals status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
Default:
Disabled
Options:
0 = Disabled
6-24
1 = Enabled
1 = Enabled
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
2 = Required