Omron V430-F-series User Manual page 153

Auto focus multi code reader
Table of Contents

Advertisement

Pharmacode
Bar Width Status (Pharmacode)
Definition:
If set to Mixed, the reader will autodiscriminate between narrow bars and
wide bars. If set to All Narrow, all bars will be considered as narrow bars. If
set to All Wide, all bars will be considered as wide bars. If set to Fixed
Threshold, it will use the fixed threshold value to determine whether the
bars are narrow or wide. The Bar Width Status setting will be ignored
when the reader is able to tell the difference between the narrow and the
wide bars.
Serial Cmd:
<K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,back-
ground color>
Default:
Mixed
Options:
0 = Mixed
1 = All Narrow
2 = All Wide
3 = Fixed Threshold
Direction (Pharmacode)
Definition:
Specifies the direction in which a symbol can be read.
Serial Cmd:
<K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,back-
ground color>
Default:
Forward
Options:
0 = Forward
Fixed Threshold Value (Pharmacode)
Definition:
Used when Bar Width Status is set to Fixed Threshold. Defines the
minimum difference in pixels that will distinguish a narrow bar from a wide
bar.
Serial Cmd:
<K477,status,fixed symbol length status,fixed symbol length,minimum
number of bars,bar width status,direction,fixed threshold value,back-
ground color>
Default:
10
Options:
1 to 65535
6-28
1 = Reverse
Auto Focus Multi Code Reader V430-series User's Manual (Z392)