Fixed Pattern Damage
Definition:
Fixed Pattern Damage is calculated in accordance with the ISO 15415
specification.
When enabled, the Fixed Pattern Damage is attached to the symbol
output data as a value.
Serial Cmd:
<K725, aperture, overall, contrast, modulation, reflectance margin, fixed
pattern damage, axial non-uniformity, grid non-uniformity, unused
ECC>
Default:
Disabled
Options:
0 = Disabled
Axial Non-Uniformity
Definition:
Axial Non-Uniformity is calculated in accordance with the ISO 15415
specification. The Axial Non-Uniformity grading is defined as follows.
A (4.0) if AN
B (3.0) if AN
C (2.0) if AN
D (1.0) if AN
F (0.0) if AN
When enabled, the Axial Non-Uniformity is attached to the symbol out-
put data as a value.
Serial Cmd:
<K725, aperture, overall, contrast, modulation, reflectance margin, fixed
pattern damage, axial non-uniformity, grid non-uniformity, unused
ECC>
Default:
Disabled
Options:
0 = Disabled
Auto Focus Multi Code Reader V430-series User's Manual (Z392)
1 = Enabled
0.06
0.08
0.10
0.12
>
0.12
1 = Enabled
Symbol Quality
8-19