Install a Fan Module
The fan modules are keyed to ensure that they are installed in the correct orientation.
3.
Press down on the fan module to fully seat the fan module.
4.
Verify that the fan module status indicator (LED) on the replacement fan module
is not illuminated.
5.
Install the server top cover.
See
"Install the Server Top Cover" on page
6.
Verify that the Top Fan Fault LED on the front of the server and the Fault-Service
Required LEDs on the front and back of the server are off.
See
"Server System-Level Status Indicators" on page 31
and interpreting system status indicators.
7.
Consider your next step:
If you installed the fan module as part of another procedure, return to that procedure.
Otherwise, if you powered off the server, return the server to operation. See
Server to Operation" on page
Related Information