Oracle Exadata Storage Server X7-2 EF Service Manual page 109

Hide thumbs Also See for Exadata Storage Server X7-2 EF:
Table of Contents

Advertisement

See
"Install the Server Top Cover" on page
Return the server to the normal rack position.
c.
See
"Return the Server to the Normal Rack Position" on page
d.
Reconnect the power cords and data cables to the server.
See
"Reconnect Power and Data Cables" on page
Power on the server.
e.
See
"Power On the Server" on page
Verify that the power supply AC OK LED is lit.
6.
(Optional) Use Oracle ILOM to clear server DIMM faults.
DIMM faults are automatically cleared after a new DIMM is installed. If you need to
manually clear DIMM faults, refer to the Oracle Integrated Lights Out Manager (ILOM) 4.0
Documentation Library at http://www.oracle.com/goto/ilom/docs.
If you want to move a faulty DIMM to a new DIMM slot or re-seat a DIMM for
Note -
troubleshooting, you must first manually clear the associated DIMM fault. Otherwise, the
DIMM fault might follow the DIMM to the new slot location or reoccur on the current slot
location, causing a false DIMM fault condition.
Related Information
"DIMM and Processor Physical Layout" on page 102
"DIMM Population Rules" on page 103
"Identify and Remove a DIMM" on page 105
189.