Disconnect Cables From The Server - Oracle Exadata Storage Server X7-2 EF Service Manual

Hide thumbs Also See for Exadata Storage Server X7-2 EF:
Table of Contents

Advertisement

Power Down the Server for Immediate Shutdown Using the
On/Standby Button
When you power down the server using Oracle ILOM, the server enters Standby
Caution -
power mode. Power is still directed to the service processor remote management subsystem and
power supply fans. To completely power off the server, you must disconnect the power cords
from the power supplies.
Press and hold the On/Standby button for four seconds to force the Main power
1.
off and to enter Standby power mode.
When Main power is off, the System OK LED on the front panel begins blinking,
indicating that the server is in Standby power mode. See
Indicators" on page
Disconnect the power cords and data cables from the server.
2.
See
"Disconnect Cables From the Server" on page
When you power down the server using the On/Standby button, the server enters
Caution -
Standby power mode. Power is still directed to the service processor remote management
subsystem and power supply fans. To completely power off the server, you must disconnect the
power cords from the power supplies.
Related Information
"Server System-Level Status Indicators" on page 31
"Power Down the Server for Immediate Shutdown Using the Oracle ILOM
CLI" on page 57
"Power Down the Server for Immediate Shutdown Using the Oracle ILOM Web
Interface" on page 58
"Power On the Server" on page 193

Disconnect Cables From the Server

The system supplies Standby power to the circuit boards even when the system is
Caution -
powered off.
Power Down the Server for Immediate Shutdown Using the On/Standby Button
31.
"Server System-Level Status
59.
Preparing for Service
59