Remove the Motherboard Assembly
If it does, no action is necessary.
If it does not, perform the following steps.
a.
Check to see if the replacement motherboard came with a light pipe. It
should be in a separate plastic bag.
Caution -
ii.
iii.
Install the light pipe on the replacement motherboard.
b.
180
Oracle Exadata Storage Server X7-2 EF and HC Service Manual • May 2018
If you find a replacement light pipe, skip to
If you do not find a replacement light pipe, perform the following steps to remove the
light pipe from the faulty motherboard.
i.
Insert a flat tool such as a screwdriver or penknife blade between the
light pipe housing and the light pipe.
Equipment damage. The light pipe is fragile. Handle it carefully.
Twist the tool back and forth to release the light pipe from the housing.
Pull the light pipe away from the housing.
Step
11b.