Oracle Exadata Storage Server X7-2 EF Service Manual page 32

Hide thumbs Also See for Exadata Storage Server X7-2 EF:
Table of Contents

Advertisement

Troubleshoot Hardware Faults Using the Oracle ILOM Web Interface
Status Indicator
Name
SP OK
Top Fan
Back Power
Supply Fault
System Over
Temperature
Warning
DO NOT
SERVICE
32
Oracle Exadata Storage Server X7-2 EF and HC Service Manual • May 2018
Icon
Color
Green
Amber
Amber
Back
Amber
White
State and Meaning
■ OFF – AC power is not present or the Oracle ILOM
boot is not complete.
■ STANDBY BLINK (on for 100 ms, off for 2900 ms)
– Standby power is on, but the chassis power is off
and the Oracle ILOM SP is running.
■ SLOW BLINK (1000 ms) – Startup sequence was
initiated on the host. This pattern begins soon after
you power on the server. This status indicates either:
power-on self-test (POST) code checkpoint tests
are running on the server host system, or the host
is transitioning from the powered-on state to the
standby state on shutdown.
■ STEADY ON – The server is powered on, and all
host POST code checkpoint tests are complete. The
server is in one of the following states: the server
host is booting the operating system (OS), or the
server host is running the OS.
Indicates the state of the service processor.
■ OFF – Service processor (SP) is not running.
■ SLOW BLINK – SP is booting.
■ STEADY ON – SP is fully operational.
Indicates that one or more of the internal fan modules
failed.
■ OFF – Indicates steady state; no service is required.
■ STEADY ON – Indicates service required.
Indicates that one of the server power supplies failed.
■ OFF – Indicates steady state; no service is required.
■ STEADY ON – Indicates service required; service
the power supply.
Indicates a warning for an overtemperature condition.
■ OFF – Normal operation; no service is required.
■ STEADY ON – The system is experiencing an
overtemperature warning condition.
Note -
This is a warning indication, not a fatal
overtemperature. Failure to correct this might result in
the system overheating and shutting down unexpectedly.
Indicates that the system is not ready to service.
■ OFF – Normal operation.
■ STEADY ON – The system is not ready for service.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exadata storage server x7-2 hc

Table of Contents