Wireless Opentherm Bridge (R8810); Thermostat (Dts92) To Control An Opentherm™ Boiler; On The Opentherm Bridge - Honeywell ATC928G3000 Manual

Wi-fi evohome controller
Hide thumbs Also See for ATC928G3000:
Table of Contents

Advertisement

Programmable
Thermostat (CM900RF)
To bind a Wireless OpenTherm Bridge (R8810) to a Programmable
Thermostat (CM900RF) to control an OpenTherm™ boiler...
On the Wireless OpenTherm Bridge
Press and hold the button for 15 seconds
1
(until the red LED blinks rapidly) to
clear any previous binding data
Press and hold the button again for 5
2
seconds (until the red LED blinks slowly)
On the Programmable Thermostat
Move the setting slider to the
3
Press and hold the
4
together for approximately 3 seconds until
'InSt' and 'CONTROL BINDING' is displayed
48
Wireless connectivity Guide
OFF
position
,
and
buttons
Wireless OpenTherm
Bridge (R8810)
Press
to send the binding signal to
5
the Wireless OpenTherm Bridge
The LED on the Wireless OpenTherm
Bridge should stop blinking and turn
OFF. If not go back and re-bind.