Honeywell Optiflex Installation And Setup Manual

Video controller

Advertisement

Quick Links

K0948V2 11/04 Rev. A
A A A A
D D D D
E E E E
M M M M
C C C C
A A A A
D D D D
E E E E
M M M M
C C C C
Installation and Setup Guide
Installation and Setup Guide
Installation and Setup Guide
Installation and Setup Guide
   
   
O O O O
O O O O
p p p p
t t t t
O O O O
O O O O
p p p p
t t t t
V V V V
i i i i
d d d d
e e e e
o o o o
C C C C
o o o o
n n n n
V V V V
i i i i
d d d d
e e e e
o o o o
C C C C
o o o o
n n n n
i i i i
f f f f
l l l l
e e e e
x x x x
i i i i
f f f f
l l l l
e e e e
x x x x
t t t t
r r r r
o o o o
l l l l
l l l l
e e e e
r r r r
t t t t
r r r r
o o o o
l l l l
l l l l
e e e e
r r r r

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Optiflex

  • Page 1 K0948V2 11/04 Rev. A A A A A D D D D E E E E M M M M C C C C O O O O A A A A D D D D E E E E M M M M C C C C O O O O...
  • Page 3: Table Of Contents

    NTSC Guard Tour Mode (Camera Scanning Mode) – Camera Dwell Time ...2-5 NTSC Guard Tour Mode – Camera Selection...2-5 Section 3: Setting Up Optiflex Using Symphony ... 3-1 How to Enable Video on Symphony ...3-1 How to Set Up Video Options on Symphony...3-2 Section 4: Operational Status Indicators...
  • Page 5: Introduction To Optiflex

    PC. Neither is required for local viewing at a monitor connected directly to the Optiflex unit. For information on how to obtain these services and set your system up for remote viewing and local viewing on a PC, log on to http://www.security.honeywell.com/hsce/alarmnet/optiflex.
  • Page 6: Optiflex Typical System Block Diagram

    Optiflex Installation and Setup Guide Optiflex Typical System Block Diagram A typical Optiflex System Block Diagram is shown in Figure 1. Optiflex can be used in a variety of applications. It can be: • connected through an Ethernet hub/router to a PC or Symphony for remote viewing •...
  • Page 7: Section 2: Mounting, Wiring, And Setup

    Cameras connected to Optiflex can either be triggered by system events from a Honeywell Vista control panel, from the voltage triggers provided, or both. Optiflex can also be used without any triggers at all, if the system is configured to automatically scan the cameras one at a time, or if the cameras are always on.
  • Page 8: Mounting Optiflex

    3. Secure the case back to the mounting surface using four screws (supplied). Prior to attaching the case front to the case back, be sure to wire the Optiflex as described in the "Wiring Optiflex" paragraph in this section .
  • Page 9: Wiring And Setup Of Optiflex

    Wiring and Setup of Optiflex Before wiring Optiflex, make sure power is turned off and review the important notes below. 1. Use a Listed Class 2 power supply suited for the application (see Section 5: Specifications). 2. Panel triggered UL Installations : Optiflex may be connected as a supplemental device to listed fire and/or burglar alarm control panels that support the 4204 relay module except as noted below.
  • Page 10 Optiflex Installation and Setup Guide To wire Optiflex, refer to the Summary of Connections diagram at the rear of this guide and do the following. 1. Connect the wires to the header as follows: a. Connect the (+) terminal of the supplementary power supply to header position 1 (+12VDC terminal of Optiflex (red wire)).
  • Page 11: Ntsc Output Configuration

    Switch for Guard Tour 8. Turn on the power source. Wait approximately 30 seconds while the Optiflex software loads and the video sources are detected. During this time Optiflex scans for cameras, and if they are detected begins monitoring them. If they are not detected, they will not be monitored.
  • Page 12 Optiflex Installation and Setup Guide Optiflex can be reset to its default settings by pressing and holding the top reset button for 10 seconds. The system will automatically reboot to the default settings...
  • Page 13: Section 3: Setting Up Optiflex Using Symphony

    Symphony can either be used to view video events locally when attached to a Honeywell Vista control panel, or to view events remotely over the Internet using Optiflex Connect. In either case, follow the steps below to allow the viewing of video events through Symphony.
  • Page 14: How To Set Up Video Options On Symphony

    9. Select NTSC default camera for NTSC composite monitor viewing. In order to enable remote viewing over the Internet using either Symphony or a PC, you must obtain Optiflex Connect through AlarmNet. For information on how to set your system up for remote viewing, go to http://www.security.honeywell.com/hsce/alarmnet/optiflex.
  • Page 15: Section 4: Operational Status Indicators

    RX – Flashing indicates data being received over the Ethernet connection. TX – Flashing indicates data being transmitted over the Ethernet connection. CAMERA STATUS Operational Status Indicators LEDs ETHERNET LEDs STATUS LIGHTS S E C T I O N optiflex-007-V0...
  • Page 16: Optiflex Status Leds

    On – At least one camera is detected Off – No cameras detected Flashing – At least one camera is being viewed Power On – power applied to Optiflex Off – No power applied to Optiflex USED CAMERA STATUS CAMERA...
  • Page 17: Section 5: Specifications

    (oldest images are deleted when buffer is full) Four frames/second for single camera viewing. Quad view approximately one frame/second. JPEG NETWORK 10 Base-T Ethernet TRIGGERS Eight 12VDC positive triggers Eight integrated 4204 style relays for use with Honeywell compatible Vista Control Panels...
  • Page 18 Optiflex Installation and Setup Guide...
  • Page 19 NTSC Guard Tour Mode – Camera Selection Dip Switch Use All Six Cameras for Guard Tour S E C T I O N SWITCH COMPOSITE VIDEO 10 baseT ETHERNET DETAIL C optiflex-SOC-V3 Cam-4 Cam-5 Cam-6 Guard Reserved View View View Tour 8 sec...
  • Page 20 Optiflex Installation and Setup Guide...
  • Page 21 NOTES...
  • Page 22 NOTES...
  • Page 23 Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty.
  • Page 24 ÊK0948V2pŠ ÊK0948V2pŠ ÊK0948V2pŠ ÊK0948V2pŠ K0948V2 11/04 Rev. A 165 Eileen Way, Syosset, NY 11791  Copyright 2004 Honeywell International Inc. www.honeywell.com/security...