evohome Controller
(ATC928G2000)
To bind a Mixing Valve Controller (HM80) to an evohome
Controller (ATC928G2000) "mixing valve" zone...
On the evohome Controller
Press and hold
SETTINGS
1
Press the green tick
2
Press
ZONE SETTINGS
3
Press
EDIT ZONE
4
Press on the required zone
5
Press the button next to "Application:"
6
MIXING VALVE
Press
7
On the Mixing Valve Controller
Press and hold both buttons on the
8
Mixing Valve Controller for 4 seconds
until the red light flashes
evohome Controller (ATC928G2000)
for 5 seconds
Mixing Valve Controller
On the evohome Controller
Press the bind button
9
You should receive a SUCCESS message on the
evohome Controller. If not go back and re-bind.
The Mixing Valve Controller will not provide
a heat demand to the boiler. If you want this
zone to provide a heat demand change the
Application Type from 'MIXING VALVE' to 'ZONE
VALVES' once the Mixing Valve controller is
bound. There is no need to re-bind any device
– The Mixing Valve Controller will still operate
as intended and the evohome Controller
will send the heat demand to the boiler.