Power/Error Indicator Led And Factory Reset Button; Power/Error Indicator Led And Power Modes - FLIR AX8 User Manual

Ax series s camera / sensor
Hide thumbs Also See for FLIR AX8:
Table of Contents

Advertisement

Indicator LEDs and factory reset
button
1. Factory reset button.
2. Ethernet communication indicator LED (green).
3. Power/error indicator LED (blue/red).

25.1 Power/error indicator LED and factory reset button

Note Do not hold down the factory reset button when connecting the camera to power.
Factory reset button
Indicator LED status
depression time
period
> 1 second
The power/error indica-
tor LED displays a con-
tinuous red light.
> 4 seconds
The power/error indica-
tor LED displays a
flashing red light.
> 10 seconds
The power/error indica-
tor LED displays a rap-
idly flashing red light.

25.2 Power/error indicator LED and power modes

Indicator LED status
The power/error indicator LED displays a pink
light for 10 seconds.
The power/error indicator LED displays a blue
light.
Explanation
When the factory reset button is released:
A factory reset is executed.
The main camera application is restarted.
The indicator LED status resumes the status it
had before the button was depressed.
When the factory reset button is released:
A factory reset is executed.
The main camera application is restarted.
The camera's IP settings are reset to the fac-
tory defaults (DHCP assigned).
The indicator LED status resumes the status it
had before the button was depressed.
When the factory reset button is released:
A factory reset is executed.
The camera's IP settings are reset to the fac-
tory defaults (DHCP assigned).
All added users are deleted.
All passwords are deleted.
The camera is restarted.
Explanation
Power is applied.
Normal operation.