1.16
Spot Meter Object (6C
1.16.1
Class and Instance Attributes
The following tables contain the attribute and common services information for Spot Meter.
Attribute
Instance
ID
Class
1
Revision
(Instance 0)
2
Max Instance UINT
Instance
1 - 20
1
Enable Local
Object
Parameter
Values
2
Reflected
Temp.
3
Emissivity
4
Distance
5
Enable
Spotmeter
6
Spotmeter
Pixel X-
Position
7
Spotmeter
Pixel Y-
Position
8
Spotmeter
Temp.
©Real Time Automation, Inc.
FLIR Systems Object Model version 1.22
20 Instances)
HEX-
Data
Name
Data Value
Type
UINT
1
BOOL
0: Disabled
1: Enabled
REAL
Kelvin
REAL
0.001-1.0
REAL
Meters
BOOL
0:Disable
1:Enable
DINT
DINT
REAL
Kelvin
09/15/2009
Access
Rule
Get
Get
Get/Set
Get/Set
Get/Set
Get/Set
Get/Set
Get/Set
Get/Set
Get
Comment