FLIR AX8 User Manual page 163

Ax series s camera / sensor
Hide thumbs Also See for FLIR AX8:
Table of Contents

Advertisement

1.17.4-12 Box Position X
This attribute sets the value of a particular box's position on the X-axis. The X-axis is horizontal. As this number increases from
0, the box will move from left to right.
1.17.4-13 Box Position Y
This attribute sets the value of a particular box's position on the Y-axis. The Y-axis is vertical. As this number increases from 0,
the box will move from top to bottom.
1.17.4-14 Box Min Temperature Position X
This attribute indicates where on the horizontal X-axis the minimum box temperature is located.
1.17.4-15 Box Min Temperature Position Y
This attribute indicates where on the vertical Y-axis the minimum box temperature is located.
1.17.4-16 Box Max Temperature Position X
This attribute indicates where on the horizontal X-axis the maximum box temperature is located.
1.17.4-17 Box Max Temperature Position Y
This attribute indicates where on the vertical Y-axis the maximum box temperature is located.
1.17.4-18 Box Width
This attribute sets the value of a particular box's width.
1.17.4-19 Box Height
This attribute sets the value of a particular box's height.
1.17.4-20 Temperature Display Options
This attribute controls which temperatures will be shown on IR Monitor for a particular box. When a particular bit is set to 1, then
that assigned temperature display value will be shown on IR Monitor. Acceptable range is 0 (none shown) - 7 (all shown).
©Real Time Automation, Inc.
FLIR Systems Object Model version 1.22
Value Meaning
0
Undefined
1
In the acceptable range
2
Less than the acceptable range
3
More than the acceptable range
4
Outside the acceptable range
5
Outside calibration
6
Unstable temperature
7
Temperature is compensated with delta correction
09/15/2009