FLIR AX8 User Manual page 170

Ax series s camera / sensor
Hide thumbs Also See for FLIR AX8:
Table of Contents

Advertisement

Service Code
Class
Instance
0x36
0x70
0x01
Example using Service Code 0x37:
Goal: Write Focus Position Value to 8.0
Explanation: Data field is filled with the length of the camera variable ".image.zoom.zoomFactor" followed by the ASCII representation of it,
plus 4 additional bytes of data (in this case 0x00 0x00 0x00 0x41) for the new REAL value. The new value should be passed in Little-Endian
to match EtherNet/IP. This means that the bytes are placed in order from least significant to most significant.
Service Code
Class
Instance
0x37
0x70
0x01
Example using Service Code 0x38:
Goal: Read Image Automatic Adjust Setting
Explanation: Data field is filled with the length of the camera variable ".image.contadj.adjMode" followed by the ASCII representation of it.
Service Code
Class
Instance
0x38
0x70
0x01
Example using Service Code 0x39:
Goal: Write Image Automatic Adjust Setting to "Auto"
Explanation: Data field is filled with the length of the camera variable ".image.contadj.adjMode" followed by the ASCII representation of it.
The next byte of data is the size of the new ASCII string value to follow (in this case 0x04). Then, attach the new ASCII value (in this case
"0x41 0x75 0x74 0x6F").
Service Code
Class
Instance
0x39
0x70
0x01
©Real Time Automation, Inc.
FLIR Systems Object Model version 1.22
Attribute
Data
16 2E 69 6D 61 67 65 2E 7A 6F 6F 6D 2E 7A 6F 6F 6D 46 61 63 74 6F 72
Attribute
Data
16 2E 69 6D 61 67 65 2E 7A 6F 6F 6D 2E 7A 6F 6F 6D 46 61 63 74 6F 72 00 00 00 41
Attribute
Data
16 2E 69 6D 61 67 65 2E 63 6F 6E 74 61 64 6A 2E 61 64 6A 4D 6F 64 65
Attribute
Data
16 2E 69 6D 61 67 65 2E 63 6F 6E 74 61 64 6A 2E 61 64 6A 4D 6F 64 65 04 41 75 74 6F
09/15/2009