1.18
Temperature Difference Object (6E
1.18.1
Class and Instance Attributes
The following tables contain the attribute and common services information for Temperature Difference.
Attribute
Instance
ID
Class
1
Revision
(Instance 0)
2
Max Instance
100
Internal Camera
Temp.
Instance 1-6
1
Enable Temp.
Difference
2
Value of Temp.
Difference
3
Difference
Temp. Valid
State
1.18.2
Class and Instance Services
©Real Time Automation, Inc.
FLIR Systems Object Model version 1.22
6 Instances)
HEX- -
Data
Name
Data Value
Type
UINT
1
UINT
REAL
BOOL
0:Disable
1: Enable
REAL
Kelvin
USINT
0: Undefined(U)
1: Valid (=)
2: Less Than(>)
3: More Than(<)
4: Outside(O)
5: Outside calib.(*)
6: Unstable(~)
7: Compenstated w/
delta correction(d)
09/15/2009
Access
Comment
Rule
Get
Get
Get
Get/Set
Get
Get