Description Of Instance Attributes - FLIR AX8 User Manual

Ax series s camera / sensor
Hide thumbs Also See for FLIR AX8:
Table of Contents

Advertisement

1.9.3

Description of Instance Attributes

1.9.3-1
Auto NUC
This attribute either enables or disables the Auto NUC functionality in the camera. NUC stands for non-uniformity correction. If
this attribute is enabled, the camera will auto-correct whenever necessary. If disabled, the camera will rely on the user to force an
Auto NUC when needed, see 1.9.3-2.
1.9.3-2
Force NUC
This attribute forces a NUC to execute. Since this is a momentary toggle, the read will always return 0.
1.9.3-3
Full Auto Focus
This attribute forces a coarse autofocus to execute using the entire focus range. Since this is a momentary toggle, the read will
always return 0.
1.9.3-4
Fast Auto Focus
This attribute forces a fine autofocus to execute using the nearby focus range. Since this is a momentary toggle, the read will
always return 0.
1.9.3-5
Focus Control Speed
This attribute sets the step value for a focus. The acceptable range for this attribute is 0-100. A value of 0 indicates no change, 1 is
the smallest focus step change possible, and 100 is the largest focus step change possible. Once the step change is set here, the
Focus command is executed by Attribute 6, see 1.9.3-6 for more details.
1.9.3-6
Focus Control
This attribute depends on the values of Attribute 5. If a 0 is written, no change will occur. If a 1 is written, the refocus will move
towards near focus for the amount given in Attribute 5. If a 2 is written, the refocus will move towards far focus for the amount
given in Attribute 5. All other the values are not accepted.
1.9.3-7
Focus Position
This attribute forces the camera to refocus to the absolute position provided. The range of values depends on the camera.
1.9.3-8
Digital Zoom
This attribute controls the digital zoom factor in the camera. The acceptable range of values is 1.0-8.0, where 1.0 is the lowest
zoom factor and 8.0 is the highest zoom factor.
1.9.3-9
Enable Overlay Graphics
This attribute either shows or hides the enabled overlay graphic options (Atributes 10-19) in IR Monitor. If this is disabled, it will
also hide any spot or box temperature information as well.
1.9.3-10
Overlay Graphic Camera Label
This attribute either enables or disables the overlay camera label graphic in IR Monitor.
1.9.3-11
Overlay Graphic Scale
©Real Time Automation, Inc.
FLIR Systems Object Model version 1.22
09/15/2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents