Drive Blank Installation Guidelines For The Hpe Proliant Xl170R Gen10 Server - HPE ProLiant XL170r Gen10 User Manual

Hide thumbs Also See for ProLiant XL170r Gen10:
Table of Contents

Advertisement

Description
Media Module Eth
10Gb 2p 568FLR-
MMT Adptr
1
If the component is installed in server 1 or server 2, and the server is installed in the Apollo r2200 Gen10 Chassis,
drive blanks must be installed in drive bays 1-2 and 2-2. Similarly, if the component is installed in server 3 or server 4,
and the server is installed in the Apollo r2200 Gen10 Chassis, drive blanks must be installed in drive bays 3-2 and
4-2. For more information, see Drive blank installation guidelines for the HPE ProLiant XL170r Gen10 Server.
Drive blank installation guidelines for the HPE ProLiant XL170r Gen10
Server
Depending on the chassis configuration and the component being installed in the server, it might be
necessary to limit the number of drives installed in the chassis. For more information, see List of
components with temperature requirements in the HPE ProLiant XL170r Gen10 Server.
Procedure
1. Note the server number.
2. Note the drive bays that correspond to the server.
HPE Apollo r2200 Gen10 Chassis
3. Do the following:
a. If the component is installed in server 1 or server 2, remove the drives from drive bays 1-2 and 2-2.
b. If the component is installed in server 3 or server 4, remove the drives from drive bays 3-2 and 4-2.
4. Install the drive blanks.
96

Drive blank installation guidelines for the HPE ProLiant XL170r Gen10 Server

Chassis
Number of LFF/SFF/NVMe
drives that correspond to
the server
Apollo r2800
0 to 24 drives
Gen10 Chassis
with SAS Expander
Apollo r2800
0 to 4 drives
Gen10 Chassis
with 16 NVMe
Maximum inlet ambient
temperature
30°C (86°F)
30°C (86°F)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents