Bi-Metal Gas Valve Removal And Replacement - Back Of Range - Thermador PRL304EG Service Manual

Pro grand series lp gas ranges
Hide thumbs Also See for PRL304EG:
Table of Contents

Advertisement

Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
Figure 161: Solenoid Valve and Fittings for Bake Burner – at Back of
Range
1
Gas flex tube
2
Compression nut
3
Sleeve
4
Solenoid valve outlet (to gas flex tube / bake burner)
5
Solenoid valve
6
Solenoid valve inlet (from manifold arm)
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test.
4.6.11 Bi-Metal Gas Valve Removal and Replacement – Back of
Range
There is a dedicated bi-metal gas valve for each individual broil
burner. For 48-inch ranges, the bi-metal gas valves are located and
accessible at the back of the range. For 30-inch and 36-inch ranges,
the bi-metal gas valves are located under the maintop (see Bi-Metal
Gas Valve Removal and Replacement – Under Maintop, page 56).
58300000156573_ARA_EN_B
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
Figure 162: Typical Bi-Metal Gas Valves
Figure 163: Bi-Metal Gas Valve and Connections
1
Spade wire connectors (2)
2
Bi-metal gas valve
3
Screws (2) that hold bi-metal valve to range chassis
4
Compression nut on gas tube at inlet
5
Compression nut on gas tube at outlet
Page 83 of 119