10. Remove the white plastic side connector from the potentiometer
by pressing on the connector tab. (see Figure 86).
11. Replace the XLO valve if needed.
12. Detach the XLO valve from the potentiometer by using a small
flat-blade screwdriver to gently remove the XLO valve from the
potentiometer standoffs. Then slide the potentiometer off the valve
stem (see Figure 87).
Gas Leaks
With electrical power off, carefully check for gas leaks at each gas
component that was removed, replaced, or otherwise serviced using a
gas leak detector or bubble test. For XLO valves, you may need the
electrical power to be on when testing for gas leaks. Use extreme
caution when performing gas leak testing on XLO valves with the
electrical power turned on.
Figure 86: Side Connector Tab
1
Harness connector tab
58300000156573_ARA_EN_B
Figure 87: Removing the XLO Valve from the Potentiometer