LCD-display

16 LCD-display
Wechsel ein-auf zweispaltig
Dual function: LCD display with TTF350 configuration options

16.1 Features of the LCD display

Transmitter-controlled graphic (alphanumeric) LCD display
Character height, mode-dependent
Sign, 4 digits, 2 decimal places
Bar graph display
Plug in to 4 positions each 90° apart
Display options:
Sensor 1 process data
Sensor 2 process data
Sensor 1 electrical (Ω / mV)
Sensor 2 electrical (Ω / mV)
Electronics/ambient temperature
Output/current
Output %
Display diagnostic information related to transmitter and sensor
status

16.1.1 Technical data of LCD display

Temperature range:
-20 ... 70 °C
(-50 ... -20 °C or 70 ... 85 °C no function)
Humidity:
0 ... 99% relativ humidity IEC 60068-2-78
Fig. 31
1
Exit/Cancel
2
Scroll back
Wechsel ein-auf zweispaltig
68
3
Scroll forward
4
Select

16.2 Configuration function of LCD display

Configurable TTF350 transmitter parameters per display:
All parameters
(sensor/type circuit, measuring range, leakage current signal,
etc.)
except: table-based sensor and freestyle characteristics,
Callendar van Dusen coefficients, warning and alarm limits, drift
parameters, NE107 "Maintenance required" alarm pulse signal
Software write protection for TTF350 configuration
16.3 LCD display HMI ignition-proof type B
(intrinsically safe)
Approved for use in zone 0.
Designation:
II 1G EEx ia IIC T6
Important
The Ex or ignition-proof designation is provided on the name
plate.
EC prototype test certificate: ZELM 07 ATEX 0331 U
Temperature table
Temperature
Permissible ambient temperature range
class
Device category 1
use
T6
-40 ... 40 °C
T5
-40 ... 55 °C
T4
-40 ... 85 °C
For the ambient temperature range from -50 °C to -20°C, additional
mechanical protection is required.
Safety-relevant data
Intrinsically safe EEx ia IIC explosion protection
Max. voltage
Short-circuit current
Max. power
Internal inductance
Internal capacitance
TTF350
Device category 2
use
-40 ... 40 °C
-40 ... 55 °C
-40 ... 85 °C
Supply circuit
U
= 9 V
i
I
= 65,2 mA
i
P
= 101 mW
i
L
= 0 mH
i
C
= 342 nF
i