- Connect (+) wire of Alarm Device to Alarm RELAY (NO port) wire.
- Connect (-) wire of Alarm Device to Power GND (-) wire.
8-4. Exit Button Connection
- Connect one of the wires of Exit Button to Exit Button Input.
- Connect the other wire of Exit Button to Power GND(-).
8-5. Door Contact Sensor Connection
- Connect Door Contact sensor(COM) wire to Door Contact Input.
- Connect Door Contact sensor(NO) wire to Power GND(-).
8-6. Auxiliary Input Device Connection (Applied to Input 1,2)
- Connect one wire of the Auxiliary Input Device to the Input(Input 1,2).
- Connect the other wire of Auxiliary Input Device to Power GND(-).
8-7. Wiegand Input Connection From Wiegand Reader(1, 2)
- Connect (+) wire of Reader(1,2) to +12V port of Main Unit.
- Connect (-) wire of Reader(1,2) to GND (-) port of Main Unit.
- Connect Wiegand output DATA0 wire of the additional Reader(1,2) to DATA0(Reader1,2).
- Connect Wiegand output DATA1 wire of the additional Reader(1,2) to DATA1(Reader1,2).
- When installing readers, reader1 set for entry and reader2 set for exit.
* Qualified card readers: 26bit wiegand format reader
EXAMPLE: ID_TECK
8-8. RS-232 Communication Port Connection
9-pin connector (COM Port, female) is required to connect serial communication RS-232
between Main Unit and Personal Computer.
- Connect RS-232-TX of main unit to pin number 2 of 9-pin connector.
- Connect RS-232-RX of main unit to pin number 3 of 9-pin connector.
- Connect RS-232-GND of Main Unit to pin number 5 of 9-pin connector.
- Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.
- Install and run Application Software.
8-9. RS-422 Communication Port Connection
RS-422/RS-232 converter is required to connect serial communication RS-422 between Main
Unit and Personal Computer.
- Plug in RS-232 9-pin connector of RS-422/RS-232 converter to COM1 or COM2 Port of
Personal Computer.
- Connect RS-422-TX(-) of Main Unit to RX(-) port of converter.
- Connect RS-422-TX(+) of Main Unit to RX(+) port of converter.
- Connect RS-422-RX(-) of Main Unit to TX(-) port of converter.
- Connect RS-422-RX(+) of Main Unit to TX(+) port of converter.
- Install and run Application Software.