13.2.3 Defining Outputs in Compliance with Inputs
IN/OUT DEFINE
IN/OUT DEFINE
1. EXIT
03 00 00 00 00
ICON100-20011128
'ENT'
NO
or ESC
You can program or deactivate each output to be generated and choose
how long (in seconds) they will last. There are default values as seen in the
table 2 below.
Select input sources by changing index No. with the keys <4> or <6>,
and press <ENT> key, and you'll see a cursor blinking at the first digit, from
the left, of the five couples of digit, which corresponds to relay1, relay2,
TTL1, TTL2 and buzzer, respectively. Then enter the delay times(refer to
the table below) one by one. Now, an inputs/outputs definition has
completed. For further definition, repeat the process. To end defining
inputs/outputs, press <ESC> key, and you will see the first figure of the
menu.
Note: The five couples of digit of [15] Output T/S and [16] Input/Output T/S
DISPLAY CURRENT SET
SELECT INDEX
(USE '4','6' KEY)
'ENT'
ENTER NEW TIME OR T/S INDEX
(10 DIGIT OR EVEN DIGIT) + 'ENT'
NEXT?
are time schedule indexes.
29
ID TECK
ACCESS CONTROLLER
YES or Error