Configure Through - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

66
en | A-Link Plus Application
Configuration menu
Network module
programming -> Module
1 # -> Mail Information
Network module
programming -> Module
1 # -> Encryption and
Security Settings
Network module
programming -> Module
1 # -> Maintenance
Now the control panel parameters and module parameters changed through A-Link Plus can
be downloaded to the module.
10.5.2
Configure through B450/B450-M
Enabled external network modules and configured Email parameters through A-Link Plus or
alphanumeric codepad, the control panel sends emails to assigned inbox through external
network modules when events received.
Step1: Enable network module with the alphanumeric codepad
1.
2.
3.
4.
5.
6.
Step 2: Reset module to factory default
If the parameters of the B450/B450-M with B442/B443 inserted are already set to their factory
default values, skip the steps below and go to the next set of steps.
1.
2.
3.
4.
5.
6.
7.
8.
9.
2017.10 | 03 | F.01U.298.026
Parameter
Partial mail server name / url
Mail server port
Partial mail server user name
Mail server password
Security options
Enhanced Security Enable
Web Access Enable
Panel Programming Enable
Enter the Installer passcode (the default is 1234) and press [#] to enter Installer's
Programming Mode.
Press [7][2][1] to access the Network Module menu, select Network Module 1 or 2, and
press [#].
Select 3 - Used, B4xx-M, and press [#].
Select 1 - Enable, and press [#].
Continue to press [-] until you return to Confirm to Save Parameter Changes.
Press [#] to save changes.
Power off the control panel.
Set the rotary address switch of the module to "0".
Connect the module to the computer with a male to male USB cable.
Power on the control panel.
Wait until the heartbeat LED on the B450/B450-M flashes 3 times per second and the
status LED on the B442/B443 flashes 1 time per second. The flashing indicates the
startup process has completed.
Install "Tera Term" software from the B450/B450-M CD on the computer and open it,
select the serial port named B450 Config Interface.
Press [ENTER] to enter the B450 USB login interface.
Enter passcode "B450" and press [ENTER]. The main menu opens.
Enter "5" to select Reset To Factory Default. At the message "Are you sure (Y to default, N
to exit)", input "Y" to confirm. The interface returns to the main menu.
Value
smtp.163.com
465
test@163.com
******
Encrypted
Enable
Enable
Enable
Installation Guide
Control Panel
Remark
Example
Sent Items (example)
Password of Sent Items
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents