This output operates when the "2 Point" button (RADION) on the 4-button keyfob is toggled
ON. The output is reset when this button is toggled OFF manually or toggled off automatically
when the ON time expires if output polarity is from 3 to 6 or from 10 to 13.
If you select Option 8 in Location 492, this output does not operate and arms the system in
STAY Mode 1 only.
2,13 Radio Control Output 1 – Not in AWAY Mode
This output operates when the "1 Point" button (RADION) on the 4-button keyfob is toggled
ON when the system is disarmed or armed in STAY Mode 1 or STAY Mode 2. The output is
reset when this button is toggled OFF manually or automatically toggled off when the ON time
expires if output polarity is from 3 to 6 or from 10 to 13. The output does not operate when
the system is armed in AWAY Mode.
2,14 Radio Control Output 2 – Not in AWAY Mode
This output operates when the "2 Point" button (RADION) on the 4-button keyfob is toggled
ON when the system is disarmed or armed in STAY Mode 1 or STAY Mode 2. The output is
reset when this button is toggled OFF manually or automatically toggled off when the ON time
expires if output polarity is from 3 to 6 or from 10 to 13. The output does not operate when
the system is armed in AWAY Mode.
If you select Option 8 in Location 492, this output does not operate and arms the system in
STAY Mode 1 only.
2,15 Communications Failure after Three Unsuccessful Calls
This output operates after the communicator makes three unsuccessful calls to any one used
receiver. The output is reset when all messages are transmitted , or six unsuccessful or no
calls to used receivers.
3,0 Communications Failure
This output operates when either of the communication routes fault. The output is reset when
both route faults clear.
3,1 Report Disabled
This output operates when the communicator reporting functions allowed option (1) in
Location 177 is not selected. The output is reset when Option 1 is selected.
3,2 Report Active
This output operates when the transmission configuration of two paths for PSTN or CSVIP or
email is not able to transmit data. The output is reset when at least one path's transmission
configuration for PSTN or CSVIP or email is able to transmit data.
3,3 Ring Detect
This output operates when an incoming call is detected by the control panel. The output is
reset when the ringing stops or when the call is answered.
3,4 Codepad / Keyfob Panic (Multi-Break)
This output operates when a Panic Alarm is initiated from the codepad or keyfob. The output
operates for 200 ms if the polarity is programmed as 1 or 8. You can program the time base
and multiplier to increase the period during which the output operates.
3,5 Mimic Zone 1
3,6 Mimic Zone 2
3,7 Mimic Zone 3
3,8 Mimic Zone 4
3,9 Mimic Zone 5
3,10 Mimic Zone 6
3,11 Mimic Zone 7
3,12 Mimic Zone 8