Partitioning; Programming; Partitioning Options 1 - Bosch Solution 2000 Installation Manual

Hide thumbs Also See for Solution 2000:
Table of Contents

Advertisement

144
en | Partitioning
19

Partitioning

The Control Panel includes the partitioning feature, which can effectively transform your single
control panel into two separate areas. Normally, arming and disarming the system turns the
entire system on or off. When Control Panel is partitioned, you can arm or disarm an individual
area without affecting the other area. Partitioning is extremely useful when you want to secure
sheds, dual occupancy dwellings, accessory dwellings, shops, and offices.
19.1

Programming

Locations 500 and 501 apply only to a partitioned Control Panel.
These locations have up to four options. You can select any combination of these options by
programming a single value. Calculate this value by adding the option bit numbers together.
19.1.1

Partitioning Options 1

Item
Partitioning Options 1
1 – First To Disarm/Last To Arm Reporting
Select this option if only one Arm/Disarm Report is required for a partitioned system. Instead
of sending individual Arm/Disarm reports for each area, an Arm Report is sent only after both
areas are armed and a Disarm Report is sent as soon as one area is disarmed.
The reports are sent with the User Codes allocated to the specific area. You must allocate the
user codes to the specific area and program user codes to have a priority level set with no
arm/disarm reports.
Notice!
This option is applicable only when all User Codes have a priority level set with no arm/
disarm reports. If User Codes have priority levels set to Arm/Disarm Reports, an Arm/Disarm
report is always sent when any area is disarmed or armed, regardless of whether the area was
first to disarm or last to arm.
4 – Reset Sirens from Any Area Allowed
This option applies only to a partitioned control panel. If this option is selected, any valid User
Code from Area 1 or Area 2 can reset the horn speaker, strobe, or bell outputs while in alarm.
This option does not allow a User Code allocated to one area to disarm another area.
19.1.2
Partitioning Options 2
Item
Partitioning Options 2
2017.10 | 03 | F.01U.298.026
Location
Option
0500
1 = First to Disarm/Last to Arm reporting
2 = Reserved
4 = Reset sirens from any area allowed
8 = Reserved
Location
Option
0501
1 = Reserved
2 = User codes allowed to arm/disarm both
areas at same time (Code [0][#])
4 = Reserved
8 = Reserved
Installation Guide
Control Panel
Default
New
0
Default
New
0
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 3000

Table of Contents