54
en | System Functions
2.
3.
7.2.6
Change Domestic Phone Numbers
See also
–
7.2.7
Change Telco Arm/Disarm Sequence
See also
–
7.2.8
Setting STAY Mode 2 Bypass Zone
See also
–
7.2.9
Turning Outputs On and Off
If an output is programmed for remote operation, you can turn the remote output on or off
using this Master Code function or remotely using the A-Link Software or smartphone
application (RSC).
To use this Master Code function, you must program one or more of the outputs with these
Output Event Types, refer to Output Event Types, page 123.
Remote control output 1 = Output Event Type 2,8
Remote control output 2 = Output Event Type 2,9
Remote control output 3 = Output Event Type 2,10
Remote control output 4 = Output Event Type 6,2
Remote control output 5 = Output Event Type 6,3
......
Remote control output 22 = Output Event Type 7,4
To turn an output on from the codepad:
1.
2.
3.
4.
Example
If Output 2 is programmed as 2,9,1,0,0,0 in Locations 442 to 447, the Master Code holder can
turn on this output by entering:
[2 5 8 0 5][AWAY][2][AWAY][AWAY]
To turn an output off from the remote codepad:
1.
2.
3.
2017.10 | 03 | F.01U.298.026
Enter the RADION keyfob number (301 to 332) you want to delete, followed by the [#]
button.
Press the [*] button to delete the RADION Keyfob.
Change Domestic Phone Numbers, page 45
Change Telco Arm/Disarm Sequence, page 46
Setting STAY Mode 2 Bypass Zones, page 47
Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and
AWAY indicators flash.
Enter the number of the output (1 to 22) and press [AWAY]. Three beeps sound and the
output turns on.
Repeat Step2 to turn on another output.
Press [AWAY] to exit from this function. Two beeps sound and the STAY and AWAY
indicators are extinguished.
Enter your Master Code and press [5][AWAY]. Three beeps sound and the STAY and
AWAY indicators flash.
Enter the number of the output (1 to 20) and press [STAY]. Two beeps sound and the
output turns off.
Repeat Step2 to turn off another output.