Danfoss VLT 6000 series Operating Instructions Manual page 167

Hvac frequency converters
Hide thumbs Also See for VLT 6000 series:
Table of Contents

Advertisement

PNU
Parameter
#
description
600
Operating data: Operating hours
601
Operating data: Hours run
602
Operating data: kWh counter
603
Operating data: Number of cut-ins
604
Operating data: Number of overtemps
605
Operating data: Number of overvoltages
606
Data log: Digital input
607
Data log: Control word
608
Data log: Status word
609
Data log: Reference
610
Data log: Feedback
611
Data log: Output frequency
612
Data log: Output voltage
613
Data log: Output current
614
Data log: DC link voltage
615
Fault log: Error code
616
Fault log: Time
617
Fault log: Value
618
Reset of kWh counter
619
Reset of hours-run counter
620
Operating mode
621
Nameplate: Unit type
622
Nameplate: Power component
623
Nameplate: VLT ordering no.
624
Nameplate: Software version no.
625
Nameplate: LCP identification no.
626
Nameplate: Database identification no.
627
Nameplate: Power component identification no.
628
Nameplate: Application option type
629
Nameplate: Application option ordering no.
630
Nameplate: Communication option type
631
Nameplate: Communication option ordering no.
655
Fault log: Real time
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the
same parameter can have four different data
values. "No" means that the data value will be
the same in all four setups.
Conversion index:
This number refers to a conversion figure to
be used when writing or reading by means
of a frequency converter.
MG.61.A5.02 - VLT is a registered Danfoss trademark
®
VLT
6000 HVAC Series
Factory setting
Range
No reset
No reset
Normal function
Conversion index
74
2
1
0
-1
-2
-3
-4
Data type:
Data type shows the type and length of the telegram.
Data type
3
4
5
6
7
9
Changes
4-Setup
Conversion
during operation
index
No
No
74
No
No
74
No
No
3
No
No
0
No
No
0
No
No
0
No
No
0
No
No
0
No
No
0
No
No
-1
No
No
-3
No
No
-1
No
No
-1
No
No
-2
No
No
0
No
No
0
No
No
0
No
No
0
Yes
No
0
Yes
No
0
Yes
No
0
No
No
0
No
No
0
No
No
0
No
No
0
No
No
0
No
No
-2
No
No
0
No
No
0
No
No
0
No
No
0
No
No
0
No
No
-4
Conversion factor
0.1
100
10
1
0.1
0.01
0.001
0.0001
Description
Integer 16
Integer 32
Unsigned 8
Unsigned 16
Unsigned 32
Text string
Data
ype
7
7
7
6
6
6
5
6
6
3
4
3
6
3
6
5
7
3
5
5
5
9
9
9
9
9
9
9
9
9
9
9
7
167