Danfoss VLT 6000 series Operating Instructions Manual page 164

Hvac frequency converters
Hide thumbs Also See for VLT 6000 series:
Table of Contents

Advertisement

PNU
Parameter
#
description
300
Terminal 16, Digital input
301
Terminal 17, Digital input
302
Terminal 18, Digital input
303
Terminal 19, Digital input
304
Terminal 27, Digital input
305
Terminal 29, Digital input
306
Terminal 32, Digital input
307
Terminal 33, Digital input
308
Terminal 53, analogue input voltage Reference
309
Terminal 53, min. scaling
310
Terminal 53, max. scaling
311
Terminal 54, analogue input voltage No operation
312
Terminal 54, min. scaling
313
Terminal 54, max. scaling
314
Terminal 60, analogue input current Reference
315
Terminal 60, min. scaling
316
Terminal 60, max. scaling
317
Time out
318
Function after time out
319
Terminal 42, output
320
Terminal 42, output, pulse scaling
321
Terminal 45, output
322
Terminal 45, output, pulse scaling
323
Relay 1, output function
324
Relay 01, ON delay
325
Relay 01, OFF delay
326
Relay 2, output function
327
Pulse reference, max. frequency
328
Pulse feedback, max. frequency
364
Terminal 42, bus control
365
Terminal 45, bus control
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the
same parameter can have four different data
values. "No" means that the data value will be
the same in all four setups.
Conversion index:
This number refers to a conversion figure to
be used when writing or reading by means
of a frequency converter.
164
Factory setting
Reset
Freeze output
Start
Reversing
Coasting stop, inverse
Jog
No operation
No operation
0.0 V
10.0 V
0.0 V
10.0 V
4.0 mA
20.0 mA
10 sec.
Off
0 - I
0-20 mA
MAX
5000 Hz
0 - f
0-20 mA
MAX
5000 Hz
Alarm
0.00 sec.
0.00 sec.
Running
5000 Hz
25000 Hz
0
0
Data type:
Data type shows the type and length of the telegram.
Data type
3
4
5
6
7
9
MG.61.A5.02 - VLT is a registered Danfoss trademark
®
VLT
6000 HVAC Series
Range
Changes 4-Setup
during operation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.0 - 10.0 V
Yes
Yes
0.0 - 10.0 V
Yes
Yes
Yes
Yes
0.0 - 10.0 V
Yes
Yes
0.0 - 10.0 V
Yes
Yes
Yes
Yes
0.0 - 20.0 mA
Yes
Yes
0.0 - 20.0 mA
Yes
Yes
1 - 99 sec.
Yes
Yes
Yes
Yes
Yes
Yes
1 - 32000 Hz
Yes
Yes
Yes
Yes
1 - 32000 Hz
Yes
Yes
Yes
Yes
0 - 600 sec.
Yes
Yes
0 - 600 sec.
Yes
Yes
Yes
Yes
Depends on
Yes
Yes
input terminal
0 - 65000 Hz
Yes
Yes
0.0 - 100 %
Yes
Yes
0.0 - 100 %
Yes
Yes
Conversion index
74
2
1
0
-1
-2
-3
-4
Description
Integer 16
Integer 32
Unsigned 8
Unsigned 16
Unsigned 32
Text string
Conversion
Data
index
type
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
0
5
-1
5
-1
5
0
5
-1
5
-1
5
0
5
-4
5
-4
5
0
5
0
5
0
5
0
6
0
5
0
6
0
5
0
6
0
6
0
5
0
6
0
6
-1
6
-1
6
Conversion factor
0.1
100
10
1
0.1
0.01
0.001
0.0001