Table 8 (Cont.): BARCODE (Native Commands)
Escape Sequence
ESC [ ; P2 ; P3 ; P4 ; P5 ; P6 ; P7 SP z
BARCODE Programming
Note: A switch from uni-directional to bidirectional printing is only possible if the parameter UNI-
DIRECT.CMD is set to YES via operator panel or ESC-sequence.
ESC [ ? 0 h
ESC [ ? 0 l
Appendix D IBM ProPrinter 4207, 4208 XL 24 Quick Reference
Mnemonic
Function
BH
Barcode Header
P2: Barcode typ
P3: Height of barcode
P4: Width of the thin bars
P5: Width of the thin gaps
P6: Ratio width to thin (bars/gaps)
P7: Uni-directional or bi-directional printing
SMBC
Set Mode Barcode
RSBC
Reset Mode Barcode
0 : or not programmed: means no changes
1 : uni-directional printing in LQ
2 : bi-directional printing in LQ
3 : uni-directional printing in NLQ
4 : bi-directional printing in NLQ