Electrical/Environmental Requirements And Characteristics - Toshiba Strata DK14 Installation And Maintenance Manual

Strata dk series. digital business telephone solutions
Hide thumbs Also See for Strata DK14:
Table of Contents

Advertisement

DK424 Installation
Site Requirements

Electrical/Environmental Requirements and Characteristics

See
Table 5-1
Table 5-1
Summary of Electrical/Environmental Characteristics
DK424 Primary Power
Input AC
AC amps for seven-cabinet system
AC frequency
Watts per cabinet (continuous)
Watts for six cabinet system (continuous)
DK424 Maximum Peak AC Input Current
1 cabinet – 2.5 amps
2 cabinets –5.0 amps
3 cabinets – 7.5 amps
4 cabinets – 10.0 amps
Environmental Specifications
Operating temperature
Operating humidity
Storage temperature
Power Supply
DC voltage output specification
Battery Charger Characteristics
PESU (Circuits 1 and 2)
Ring voltage
Ringing capability
RSTU2 or RDSU
Ring voltage
Ringing capability
RSTU2 Message Waiting voltage
RSTU2 or PESU modem interface data rate
BTU Rating
PDKU (5)
RCOU/RCOS (1)
RCTUB (1)
DKTs (40)
Traffic Rating Characteristics
9 CCS per station system-wide
36 CCS per ACD/SMIS station
There are system limits for the number of simultaneous Agents depending on traffic. See the Strata DK424 Call
Note
Center Solutions General Description for details.
5-4
for the DK424 electrical/environmental requirements and characteristics.
±
115VAC
10VAC
20 amp circuit
50/60 Hz
180
845
5 cabinets – 11.5 amps
6 cabinets –15.0 amps
7 cabinets – 17.5 amps
32~104° F (0~40° C)
20~80% relative humidity without condensation
-4~158° F (-20~70° C)
-24VDC (-26.3~-27.8VDC)
+5VDC (+4.5~+5.5VDC)
-5VDC (-4.5~-5.5VDC) - Expansion Cabinet only
Charger: current limiting
Nominal float voltage: 2.275 volts/cell
Charge current: 0.7 amps maximum
Battery discharge cut-off voltage: 20.5
Square wave output with high/low option jumper:
±
Low position 130
20VDC peak-to-peak (no-load)
±
High position, 190
25VDC peak-to-peak (no-load)
2 ringers maximum per circuit, high or low position
80V RMS sine wave
1.5 REN per circuit, with or without Message Waiting
-90 VDC/one telephone per circuit (max.)
14,400 bps maximum
190 BTUs (56 watt hours) per cabinet
±
0.5VDC
Strata DK I&M