Toshiba Strata DK14 Installation And Maintenance Manual page 282

Strata dk series. digital business telephone solutions
Hide thumbs Also See for Strata DK14:
Table of Contents

Advertisement

DK40i/DK424 Universal Slot PCBs
RSIU, RSIS, RMDS RS-232/Modem Interface Unit
2-connector Ribbon Cable
(supplied with RCTU)
Install ribbon
cables as shown
3-connector Ribbon Cable
(supplied with RSIU)
Figure 7-24 RSIU Installed into an Existing System without DID and/or Tie Lines
To move the PCB to the next highest slot
1. Identify (mark) the attendant console and all station PCB wiring connectors so they can be
removed and then reinstalled on the same PCB later (console station PCBs include: PDKU,
RDSU, PEKU, PESU, RSTU, PSTU and RATU PCBs).
2. Turn system power OFF.
3. Disconnect the connectors from the attendant console and all station PCBs listed in Step 1.
4. Remove all station PCBs listed in Step 1.
5. Install each PCB that was removed in Step 4 into the next highest empty station PCB slot
number. Skip over all other types of PCBs that were not removed. Example: If a PDKU was
originally in slot 11 and a PSTU was in slot 12, the PDKU is moved to slot 12 and the PSTU is
moved to slot 13. The programming telephone will then be on the 6th circuit (port 005; or, 013
until Program 03 Code 49 is set for slot 11) of the PDKU in slot 12.
6. Connect all PCB connectors that were removed back into the same PCBs they were removed
from in Step 3.
7. Turn the system power ON and note that the programming telephone is on port 13 and all other
ports are shifted up by eight ports. Program slot 11 with Code 49 and all other slots with the
appropriate codes using Program 91-1 and/or 03.
Next, cycle system power OFF (five seconds) and ON, or, run Program 91-2 to transfer
Program 03 data from temporary to working memory. At this time the programming telephone
changes from port 13 to port 005 and all other ports shift down by eight ports.
7-48
DK424 Base Cabinet with RCTUC3 / D3
or RCTUBA3 / RCTUBB3 / RCTUE3 / RCTUF3
Ribbon Cable
SLOT
R11
RCTU
RCTUC3 or
RCTUBA3
PCB
or
TYPE
RCTUE3
RCTUD3
or RCTUBB3
or RCTUF3
Port 1
Port 2
Ribbon Cable
Port 3
Install ribbon
cables as shown
Port 4
SLOT
S11
S12
S13
RSIU
PDKU
or
RSIS
PEKU
or
RMDS
DK424 Base Cabinet
with RCTUA3
Port 1
Port 2
Port 3
Port 4
R11
RCTU
S11
S12
S13
RSIU
PDKU
RCTUA3
or
PCB
RSIS
PEKU
TYPE
or
RMDS
1815
Strata DK I&M
5/99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk40iStrata dk424

Table of Contents