The location must not be:
Subject to extreme heat or cold
Subject to corrosive fumes, dust, or other airborne contaminants
Subject to excessive vibration
Next to television, radio, office automation, or high frequency equipment
If reserve power is to be installed for the Strata DK40i, the batteries will require a well-ventilated
location close (within nine feet) to the DKSUB40 (the optional Toshiba-supplied battery cable is
nine feet in length).
Table 3-1
provides a summary of the electrical and environmental characteristics
Table 3-1
Summary of Electrical/Environmental Characteristics
DK40i Primary Power
Input AC (Power Supply Specification)
AC frequency
Power
AC input current
Environmental Specifications
Operating temperature
Operating humidity
Storage temperature
Power Supply
DC voltage output specification
Battery Charger Characteristics
KSTU2, PSTU or PESU (Circuits 1 and 2)
Ring Voltage
Ringing capability
KSTU2, PSTU, or PESU modem interface
data rate
RSTU, RSTU2 or RDSU
Ring Voltage
Ringing capability
RSTU2 Message Waiting Voltage
RSTU, RSTU2, or RDSU modem interface
data rate
Traffic Rating Characteristics
9 CCS per station system-wide
Strata DK I&M 5/99
85~135VAC
50/60 Hz
DK40i - 75 watts maximum
1.8A maximum
32~104° F (0 ~40° C)
20~80% relative humidity without condensation
-4~158° F (-20~70° C)
-24VDC (-25.94~-28.66VDC)
+5VDC (+4.5~+5.5VDC)
-5VDC (-4.5~-5.5VDC) - Expansion KSU only
Charger: current limiting
Nominal float voltage: 2.275 volts/cell
Charge current: 0.7 amps maximum
Battery discharge cut-off voltage: 20.5
Square wave output with high/low option jumper:
±
Low position 130
20VDC peak-to-peak (no-load)
±
High position, 190
25VDC peak-to-peak (no-load)
2 REN maximum per circuit, high or low position
14,400 bps maximum
80V RMS sine wave
1.5 REN per circuit, with or without Message Waiting
-90VDC/one telephone per circuit (max.)
14,400 bps maximum
DK40i Installation
Site Requirements
±
0.5VDC