Cabinet Power, Reserve Power, and Floor Mount Hardware Assemblies (continued)
Table 4-22
Assembly
Description
RC7C1A-
Cabinet 7 Cable Kit
1.7M
- Data and Battery
Cables
RFIF
Floor Mount Fixture
(up to 7
Kit
cabinets)
RCCB1
Conduit Connection
(up to 6
Box
cabinets)
...or RCCB2
(7 cabinets)
RPSB1
Three-outlet AC
Power Strip
RPSB2
Three-outlet AC
Power Strip - heavy
cord
RWBF
Wall bracket pair

Worksheets

The worksheets help you configure the system. Designed to make the system configuration as
orderly as possible, they also provide room to record the hardware - cabinets, PCBs, stations, and
options - that comprise the system.
Copy the worksheets as required, then fill them out in the order they are given.
Worksheet 1 – System PCB Slot Requirements
Worksheet 2 – System Cabinet Assignment Guide
Worksheet 3 – System PCB Assignment Guide
Worksheet 4 – Option Configuration Guide
Worksheet 5 – System Power Factor (PF) Check
Strata DK I&M
5/99
Used for seven cabinet installations only. Provides long data cable to
connect the sixth Expansion Cabinet to the DK424 Base Cabinet.
Provides a long battery cable to connect RBDB2 battery distribution box
to the sixth Expansion Cabinet power supply.
Provides two metal stands for mounting three or more cabinets on floor.
Three pairs of wall brackets (RWBF) are supplied with RFIF. Wall
brackets are needed to secure floor mounted systems to the wall for
safety purposes (not required to wall mount cabinets).
Conduit box required for AC and battery power connection to three or
more floor-mounted cabinets. (Not required for mounting two cabinets
on a table or any number of cabinets on a wall.)
RCCB2 is required instead of RCCB1 for seven cabinet floor mount
installations.
A licensed electrician must install this item to retain UL listing and/or
local electrical code compliance.
One RPSB1 required when installing three or four cabinets (wall or floor
mount).
Two RPSB1s required when installing five, six, or seven cabinets (wall or
floor mount). Two AC cords will exit the cabinets in some configurations.
High current carrying capacity cord for application where local electric
codes (or user) requires only one AC cord to exit four or more cabinets.
It is highly recommended to use the RPSB2 for two-cabinet installations
to accommodate further growth. Must be ordered for seven cabinet
systems.
Required for seven cabinet systems when the system is floor mounted.
Secures the seventh cabinet to the wall for safety purposes (not required
to wall mount cabinets – see RFIF).
DK424 Configuration
Function
Worksheets
4-19