Wbl; Rgn - Toshiba Strata DK14 Installation And Maintenance Manual

Strata dk series. digital business telephone solutions
Hide thumbs Also See for Strata DK14:
Table of Contents

Advertisement

To PDKU with
Bridging
Female Connector
Clips
W-BL
26
1
BL-W
1
2
W-O
27
3
O-W
2
4
W-GN
28
5
GN-W
3
6
W-BR
29
7
BR-W
4
8
W-S
30
9
S-W
5
10
R-BL
31
11
BL-R
6
12
R-O
32
13
O-R
7
14
R-GN
33
15
GN-R
8
16
R-BR
34
17
BR-R
9
18
R-S
35
19
S-R
10
20
BK-BL
36
21
BL-BK
11
22
BK-O
37
23
O-BK
12
24
BK-GN
38
25
GN-BK
13
26
BK-BR
39
27
BR-BK
14
28
BK-S
40
29
S-BK
15
30
Y-BL
41
31
BL-Y
16
32
Y-O
42
33
O-Y
17
34
Y-GN
43
35
GN-Y
18
36
Y-BR
44
37
BR-Y
19
38
Y-S
45
39
S-Y
20
40
V-BL
46
41
BL-V
21
42
V-O
47
43
O-V
22
44
V-GN
48
45
GN-V
23
46
V-BR
49
47
BR-V
24
48
V-S
50
49
S-V
25
50
66M150 Split Block
Notes
1. T/R wires are always required; PT/PR are additional power wires
required only for long station runs per
2. RS-232 cable length is max 50 ft. with 24 AWG wire. See
General Notes
Voltage levels:
T, PT = -26.3~27.8 VDC
R, PR = 0.0 VDC (GND). Reference to SG ground.
DIUs can be connected to Circuits 1~7 only if connected to PDKU1; or Circuits 1~8 on PDKU2.
DK40i: Slots 15 and 16 only support data applications.
KCDU provides circuits 1~4 only. See
Figure 8-2
MDF Wiring for Digital Telephones with RPCI-DI and PDIU-DS to PDKU
Strata DK I&M
5/99
Station Cabling
(-)
T1 (Voice/Data)
1
(GND) R1 (Voice/Data)
2
(-)
PT1 (Add Power)
3
(GND) PR1 (Add Power)
4
T2
5
R2
6
Circuit 2 to DKT 2
PT2
or PDIU-DS
7
PR2
8
T3
9
R3
10
Circuit 3 to DKT 3
PT3
or PDIU-DS
11
PR3
12
T4
13
R4
14
Circuit 4 to DKT 4
PT4
or PDIU-DS
15
PR4
16
T5
17
R5
18
Circuit 5 to DKT 5
PT5
or PDIU-DS
19
PR5
20
T6
21
R6
22
Circuit 6 to DKT 6
PT6
or PDIU-DS
23
PR6
24
(-)
T7 (Voice/Data)
25
(GND) R7 (Voice/Data)
26
(-)
PT (Add Power)
27
(GND) PR (Add Power)
28
T8
29
R8
30
Circuit 8 to DKT8
PT8
or DDSS
31
PR8
32
33
34
35
36
37
38
39
40
41
Not Used
42
43
44
45
2- or 4-wIre Modular Cord
46
To RJ11 Jack on the
Back Side of PDIU-DS
47
48
49
50
Table 3-10 on Page
3-39. PT/PR may be used with normal station runs also.
Chapter 10 – Peripheral
Tables 4-4
and
4-5
in Chapter 4 – DK424 Configuration for allowed data slots.
DK40i/DK424 Universal Slot PCB Wiring
Jacketed Twisted Pairs
24AWG (1 or 2 Pair, See Note 1)
R
GN
R1
BK
Y
PT1
W
BL
6 5 4 3 2 1
2- Or 4-Wire
DB25
Modular Cord
Female
GND
to RJ11 Jack
Connector
on Bottom
PR
of RPCI-DI
RS-232
Cable
(See Note 1)
Digital
Telephone
(with or without
PDIU or RPCI-DI)
R
GN
R8
T8
BK
Y
PT8
PR8
W
BL
6 5 4 3 2 1
GND
(-)
DB-25
PR
T
Female
Connector
DIU
TOSHIBA
RS-232
POWER
READY CONNECT
Cable
PDIU-DS
Installation.
Digital Station Wiring
T1
PR1
RJ11
(-)
GND
(-)
T
R
PT
To PC or ASCII
Terminal, etc.
2
RJ11
GND
(-)
R
PT
To Modem, Printer,
or Host Computer
etc.
2
1594
8-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk40iStrata dk424

Table of Contents