Right Side View
Cabinet No. 1
Cabinet No. 2
Two AC Power
Cords from
RPSU280 Power
Supplies
(Cabinet 1 and 2)
Figure 5-20 AC and Reserve Power, One or Two Cabinets, Wall or Floor-mounted
Important!
If local electric code allows only on AC cord from the system, install a RPSB2 in
the bottom cabinet (per
plug the RPSB2 into the dedicated wall outlet.
Strata DK I&M 5/99
PBTC-3M Cable
to BATT
Connector of
Power Supply
in Cabinet 1
RPSB2
(see Important
note below)
PBTC-3M Cable
to BATT
Connector of
Power Supply
in Cabinet 2
One AC Cord
(see Important note below)
White Wires
Two PBTC-3M
Cables
Black Wires
To Dedicated AC Outlet
(See Important Note)
115VAC ± 10VAC (11.5 Amps Max)
Figure
5-23). Plug power supplies into the RPSB2 and
RPSB280 Power Supply - Front View
DC OUT
1
POWER
DKSUB ‹
-24V
2
+5V
DKSUE ‹
3
-5V
BATT
+
-
ON
OFF
AC IN
FG
Battery Box or Rack
+
12 VOLT
Two Jumper to Connect
+
Batteries in Series
12 VOLT
(Supplied With PBTC Cable)
DK424 Installation
Reserve Power Installation
White Wire
PBTC-3M
Cable
AC
Power
Cord
1474
5-35

Advertisement