Connecting The Receiver Unit To The Junction Box - ABB LS4000 Operating Instructions Manual

Diode laser analyzer, version for measuring nh3 and h2o highest precision under harshest conditions
Hide thumbs Also See for LS4000:
Table of Contents

Advertisement

Connecting the receiver unit to the junction box

Connecting the
receiver unit
46
Connect the receiver unit to the junction box.
The wires in the connection cable are color coded to facilitate the assignment
to the terminals.
Connections to the terminal strip are made as follows:
Terminal Cable wire color
2
White
4
Brown
5
Green
6
Yellow
9
Gray
10
Pink
11
Red
14
Blue
16
Black
17
Violet
18
Gray/pink
19
Blue/red
27
White/green
28
Brown/green
29
White/yellow
30
Brown/yellow
Operating instruction LS4000 for NH
Function
+24 V
GND
TURU_A
TURU_B
AUXIF_A
AUXIF_B
AUX_IO
AO3 (4...20 mA)
DO1_A
DO1_B
DO2_A
DO2_B
T-Probe_in
T-Probe_out
P-Probe_in
P-Probe_out
and H
O
3
2
OI/LS4000/NH3/H2O-EN

Advertisement

Table of Contents
loading

Table of Contents