Getting In-Band Access; Verifying The Correct Operation; Backing Up The Running Configuration - Ruckus Wireless ICX 7150-C12P Hardware Installation Manual

Icx 7150 series
Table of Contents

Advertisement

Getting in-band access

You can access the management agent in the device from anywhere within the attached network using Telnet or other network
management software. However, you must first configure the device with a valid IP address, subnet mask, and default gateway. If you have
trouble establishing a link to the management agent, check to see if you have a valid network connection. Then verify that you entered the
correct IP address. Also, be sure the port through which you are connecting to the device has not been disabled. If it has not been
disabled, then check the network cabling that runs between your remote location and the device.

Verifying the correct operation

Check the LEDs to verify operation of functional parts. The following commands can be useful to establish an operational baseline for the
Ruckus FastIron Command Reference for more information on these commands.
device. Refer to the
show chassis
show version
show cpu
show flash
show files
show run
show boot-preference
show configuration
show running-config
show logging

Backing up the running configuration

Use the write memory command to replace the startup configuration with the running configuration every time you make changes to the
device configuration. To back up the device configuration to an external TFTP server, use the copy running-config tftp command.
device# copy running-config tftp 2001:DB8:e0ff:7837::3 newrun.cfg
This command example copies the running configuration to a TFTP server with the IPv6 address of 2001:DB8:e0ff:7837::3 and names the
file on the TFTP server newrun.cfg.
Ruckus ICX 7150 Switch Hardware Installation Guide
Part Number: 53-1004928-05
Initial Setup and Verification

Backing up the running configuration

81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents