SECTION 2
2.2

MECHANICAL SPECIFICATIONS

Weight:
Height:
Width:
Depth:
Installation Clearance:
2.3

ENVIRONMENTAL SPECIFICATIONS

Air Flow:
Noise level:
Ambient Temperature:
Relative Humidity:
(non-condensing)
Elevation:
Heat Dissipation at 50kW,
62.5kVA load:
Pollution Environment:
Pacific Power Source ©2013
1550 Lbs (705 Kg)
72" (183cm)
36" (91.5cm)
30" (76.2cm)
36" (91.5cm) at front of cabinet for service,
12" (30.5cm) at top for airflow
0 side and rear
1200 CFM (566 l/s) bottom intake, top exhaust
65dbA at 3 feet
Operating 0 to 40ºC
Storage -10 to +70ºC
0 to 80% (standard configuration)
0 to 95% (conformal coated PCB option)
Operating 6500 Ft.(1970 m)
Derate to 70% at 11,500 Ft.(3480 m)
Storage 40,000 Ft.(12,120 m)
20 kBTU/hr.
Degree 2 or better
Indoor Use Only
2-3
SPECIFICATIONS