SECTION 4
4.6

FEATURE CONNECTORS

This paragraph describes the Feature Connectors contained within the MS-
Series AC Power Source, their purpose, location, and pin numbers. The use of
these connectors is optional. Refer to figure 4.6 for location of these connectors.

4.6.1 P1, P2 PARALLELING

These are used for Paralleling cabinets in multiple cabinet systems. They are
DB25P type. Pin numbers are as follows:
Pin#
Description
1
ØA (Error Signal)
2
ØB (Error Signal)
3
ØC (Error Signal)
4
Common (Error Signal)
5
Triangle Wave Sync
6
Master on line
7
Remote mode 0
8
Remote mode 2
9
Remote Emer Off
10
Remote Start
11
ØA System Amps
12
ØB System Amps
13
ØC System Amps
14-17
Gnd
18
+12VDC
19
Ext Emer Off
20-22
No Connection
23-25
Gnd