SECTION 3

CHANGING INPUT VOLTAGE

1:
Verify no input power is connected.
Open Input Circuit Breaker.
2:
Remove front covers and sub-panels.
Remove rear panel.
3:
Remove input circuit breaker CB1.
Install new CB1 with correct amperage for new input voltage.
NOTE: Wires between CB1 and the terminal block on the Input
Power Panel must be sized appropriately for the new input power
form, see Table 3.6.1 for wire size reference.
4:
Remove input fuses F1, F2 and F3.
Install new fuses with correct amperage for new input voltage.
5:
Rewire T1 and T2 per fig 3.3.1, 3.3.2, 3.3.3 or 3.3.4 as required
6:
Reinstall rear panel.
Reinstall front covers and sub-panels.
7:
Go to section 4.3.1 for first time operation.
The system may be configured for any of the following input voltages:
INPUT VOLTAGE
Actual
480
480
448
480-7%,
430
480-10%, 416+3%, 400+8%
416
416,
398
400,
380
380
366
400-9%,
348
380-8%
240
240,
208
208,
190
208-9%
Pacific Power Source ©2013
Nominal
416+8%
400+4%, 380+10%
416-4%, 380+5%
416-9%, 400-4%
380-4%
208+15%
240-13%
3-7
INSTALLATION
Fig.
INPUT
TAPS
3.3.1
1,8
3.3.1
1,8
3.3.1
2,8
3.3.1
1,7
3.3.1
1,8
3.3.2
2,8
3.3.2
2,7
3.3.2
2,8
3.3.3
1,8
3.3.4
1,7
3.3.4
2,8
Document # 126050-10 Rev E
CONNECT
TAPS
4-5
3-5
4-5
3-5
3-6
4-6
3-5
3-6
1-5,4-8
1-5,3-7
2-6,4-8

Advertisement