VERSION 07/2014
OPERATING MANUAL
5.4.4
VOLUME FLOW
Wagner AL nozzles
inch
mm Spray angle
0.007
0.18
40°
0.009
0.23
20-30-40-50-60°
0.011
0.28
10-20-30-40-50-60°
0.013
0.33
10-20-30-40-50-60-80°
0.015
0.38
10-20-30-40-50-60-80°
0.017
0.43
20-30-40-50-60-70°
0.019
0.48
20-30-40-50-60-70-80°
0.021
0.53
20-40-50-60-80°
0.023
0.58
20-40-50-60-70-80°
0.025
0.64
20-40-50-60-80°
0.027
0.69
20-40-50-60-80°
0.029
0.75
60°
0.031
0.79
20-40-50-60°
0.035
0.90
20-40-50-60°
0.043
1.10
20-50°
0.052
1.30
50°
Volume fl ow refers to water.
Maximum ranges for continuous operation at 200
5.4.5
PERFORMANCE DIAGRAMS
Example
ORDER NUMBER DOC2340851
Volume fl ow in l/min.*
at
7 MPa
70 bar
1015 psi
0.1650
0.2060
0.2950
0.4530
0.5770
0.7310
0.9260
1.1430
1.3700
1.6200
1.8300
2.1900
2.4000
3.2200
5.0700
5.1200
/min.
Stroke frequency (
Water fl ow rate (nl/min)
at
at
10 MPa
15 MPa
100 bar
150 bar
1450 psi
2175 psi
0.2000
0.2400
0.2500
0.3090
0.3450
0.4260
0.5280
0.6600
0.6720
0.8130
0.7860
1.0640
1.0920
1.3700
1.3600
1.6900
1.5900
2.0100
1.9100
2.4000
2.1300
2.6800
2.5100
3.1700
2.7700
3.4900
3.7400
4.6900
6.0400
7.4600
6.5000
7.5200
/min)
Cobra 40-10
Cobra 40-25
23