Cleaning The Parts After Disassembly - WAGNER Cobra 40-10 Translation Of The Original Operating Manual

High-pressure double diaphragm pumps
Table of Contents

Advertisement

VERSION 07/2014
OPERATING MANUAL
10.3

CLEANING THE PARTS AFTER DISASSEMBLY

Please note:
All reusable parts (except for the electrical components) should be cleaned
thoroughly using a suitable cleaning agent.
Spare parts may have safety-relevant properties.
Defective parts, O-rings and seal sets must always be re-placed.
Incompatibility of cleaning agent and working medium!
Risk of explosion and danger of poisoning by toxic gases
In Chapter 14 the order numbers for device spare parts can be found, as well as for wearing
parts such as seals.
Use torques, greases and glues in accordance with Chapter 14.
ORDER NUMBER DOC2340851
ATTENTION
WARNING
Examine the compatibility of the cleaning agents and working
media on the basis of the safety data sheets.
50