Ventilation Of The Spray Booth; Air Supply; Product Supply - WAGNER Cobra 40-10 Translation Of The Original Operating Manual

High-pressure double diaphragm pumps
Table of Contents

Advertisement

VERSION 07/2014
OPERATING MANUAL
6.5.1

VENTILATION OF THE SPRAY BOOTH

Toxic and/or fl ammable vapor mixtures!
Risk of poisoning and burns
6.5.2

AIR SUPPLY

You must ensure that only dry, clean atomizing air is used in the spray gun. Dirt and
moisture in the atomizing air worsens the spraying quality and spraying pattern.
Hose connections
Risk of injury and damage to the device.
6.5.3

PRODUCT SUPPLY

Bursting hose, bursting threaded joints!
Danger to life from injection of product
ORDER NUMBER DOC2340851
WARNING
Operate the device in a spray booth approved for the working
materials.
– or –
Operate the device on an appropriate spraying wall with the
ventilation (extraction) switched on.
Observe national and local regulations for the outgoing air
speed.
WARNING
Do not exchange hose connections of product hose and air
hose.
DANGER
Ensure that the hose material is chemically resistant to the
sprayed products.
Ensure that the spray gun, threaded joints, and product hose
between the device and the spray gun are suitable for the
pressure generated in the device.
Ensure that the following information can be seen on the high-
pressure hose:
- Manufacturer
- Permissible operating pressure
- Date of manufacture.
28