Volume Flow - WAGNER Cobra 40-10 Translation Of The Original Operating Manual

High-pressure double diaphragm pumps
Table of Contents

Advertisement

Operating manual High-pressure double diaphragm pumps Cobra 40-10; Cobra 40-25
5   Description
N
F
O
R
5.5.4   Volume Flow
WAGNER AL nozzles
Ø inch
Ø mm
0.007
0.18
0.009
0.23
0.011
0.28
0.013
0.33
0.015
0.38
0.017
0.43
0.019
0.48
0.021
0.53
0.023
0.58
0.025
0.64
0.027
0.69
0.029
0.75
0.031
0.79
0.035
0.90
0.043
1.10
0.052
1.30
* Volume flow refers to water.
Order number 2340851 | Edition 05/2022
Cobra 40-10
G
B_07938
Spray angle
40°
20-30-40-50-60°
10-20-30-40-50-60°
10-20-30-40-50-60-80°
10-20-30-40-50-60-80°
20-30-40-50-60-70°
20-30-40-50-60-70-80°
20-40-50-60-80°
20-40-50-60-70-80°
20-40-50-60-80°
20-40-50-60-80°
60°
20-40-50-60°
20-40-50-60°
20-50°
50°
Cobra 40-25
S
U
Volume flow* in l/min
7 MPa
10 MPa
70 bar
100 bar
1015 psi
1450 psi
0.17
0.20
0.21
0.25
0.30
0.35
0.45
0.53
0.58
0.67
0.73
0.79
0.93
1.09
1.14
1.36
1.37
1.59
1.62
1.91
1.83
2.13
2.19
2.51
2.40
2.77
3.22
3.74
5.07
6.04
5.12
6.10
S
U
15 MPa
Maximum
150 bar
ranges for
2175 psi
continuous
operation
at 200 DH/
min.
0.24
Cobra
40-10
0.30
0.43
0.66
0.81
1.06
1.37
1.69
2.01
2.40
Cobra
40-25
2.68
3.17
3.49
4.69
7.46
7.52
25