EDITION 01/2012
OPERATING MANUAL
4.3.4
VOLUME FLOW
Wagner Airless nozzle
ø inch
ø mm Spray angle
0.007
0.18
40°
0.009
0.23
20-30-40-50-60°
0.011
0.28
10-20-30-40-50-60°
0.013
0.33
10-20-30-40-50-60-80°
0.015
0.38
10-20-30-40-50-60-80°
0.017
0.43
20-30-40-50-60-70°
0.019
0.48
20-30-40-50-60-70-80°
0.021
0.53
20-40-50-60-80°
0.023
0.58
20-40-50-60-70-80°
0.025
0.64
20-40-50-60-80°
0.027
0.69
20-40-50-60-80°
0.029
0.75
60°
0.031
0.79
20-40-50-60°
0.035
0.90
20-40-50-60°
0.043
1.10
20-50°
0.052
1.30
50°
* Flow volume refers to water.
Maximum ranges for continuous operation at 200 DS/min.
4.3.5
PERFORMANCE DIAGRAMS
Example
PART NUMBER DOC322851
Volume fl ow in l/ min.*
bei
7 MPa
70 bar
1015 psi
0.1650
0.2060
0.2950
0.4530
0.5770
0.7310
0.9260
1.1430
1.3700
1.6200
1.8300
2.1900
2.4000
3.2200
5.0700
5.1200
Stroke frequency (DS/min.)
Fluid rate water (nl/min)
bei
bei
10 MPa
15 MPa
100 bar
150 bar
1450 psi
2175 psi
0.2000
0.2400
0.2500
0.3090
0.3450
0.4260
0.5280
0.6600
0.6720
0.8130
0.7860
1.0640
1.0920
1.3700
1.3600
1.6900
1.5900
2.0100
1.9100
2.4000
2.1300
2.6800
2.5100
3.1700
2.7700
3.4900
3.7400
4.6900
6.0400
7.4600
6.5000
7.5200
Cobra.
Cobra 40-10
Cobra 40-25
16