VERSION 07/2014
OPERATING MANUAL
5.5
PRESSURE REGULATOR UNIT FOR COBRA
1 Pressure regulator
2 Ball valve
3 Pressure gauge
4 Compressed air inlet
5 AirCoat fi lter regulator Cobra (accessories)
The AirCoat fi lter regulator must be mounted vertically
in all installation positions for the diaphragm pump
(see assembly manual for Filter Regulator, order
number 2328614).
Positions of the ball valve
1
Open: working position
2
Closed: The air motor can still be under pressure.
3
Vent: Operating pressure in the air motor is
vented (control pressure is still present).
ORDER NUMBER DOC2340851
1
2
3
4
3
2
1
5
B_04300
B_04301
25