OPERATING MANUAL
8.2.6

CHANGING THE OIL

The oil should be changed after 500 service hours or once a year.
Necessary accessories:
Order No. 322911 Oil fi lling set
Using hydraulic oil
Using the wrong hydraulic oil can cause a malfunction.
Use only original hydraulic oil - Wagner Order No. 322912 (250 ml or 15 cu inch).
Discharging oil
Procedure:
1
Decommission and clean the device -> Chapter 8.1.3 up to and including point 6.
2
Position device as shown in the picture and dismount the hood and casing.
3
Unscrew piston cover (1).
4
Place empty oil collector (2) under the oil tank.
5
Unscrew oil tank (3) and drain contents.
6
Unscrew and remove locking screws (4) and seals.
7
Slowly start up the pump until no oil fl ows out of the oil suction fi tting.
8
Screw in clean oil tank (3) and seal.