WAGNER Cobra 40-10 Translation Of The Original Operating Manual page 45

High-pressure double diaphragm pumps
Table of Contents

Advertisement

VERSION 07/2014
OPERATING MANUAL
Environmental pollution caused by waste oil!
Waste oil in the sewage network or spilled on the ground causes
severe environmental damage.
Groundwater pollution is liable to prosecution.
Filling hydraulic stage with oil
Procedure:
1 Turn pump (mounted on the frame) upside down.
2 Unscrew and remove threaded plug (5).
3 Unscrew 2 locking screws (4) and replace with 2 screw fi ttings (6) from the oil fi lling
set.
4 Connect hoses with Y-pieces (7).
5 Fill syringe (8) with hydraulic oil and insert into hose.
6 Move piston (9) into front end position. Use the syringe to fi ll the hydraulic stage until
the oil fl ows out of the suction fi tting into the oil tank (3) with no air bubbles.
7 Move piston (9) into rear end position. Use the syringe to fi ll the hydraulic stage until
the oil fl ows out of the suction fi tting into the oil tank (3) with no air bubbles.
8 Continue to top up the oil until the level before venting is approx. 17 mm; 0.67 inches
below the upper edge of the oil tank.
9 Screw in threaded plug (5) and tighten gently. Put pump on its side and dismount oil
fi lling set. Seal the fi ller openings tightly with 2 locking screws (4).
B_04245
7
8
ORDER NUMBER DOC2340851
CAUTION
Collect waste oil and bring it to a collection point.
Waste oil is taken back by the seller when purchasing hydraulic oil.
5
9
6
4
B_04246
45